are used when a high contact load is not required and no vibrations occur.
Nominal operating voltage: max. 250 V
Inrush and breaking current: max. 0,7 A
Switching capacity: 10 W 18 VA
Switching accuracy: approx. 0,5 % of final scale value
can be used in almost all operating conditions and are largely insensitive to vibrations.
Nominal operating voltage: max. 250 V
Inrush and breaking current: max. 1,0 A
Switching capacity: 30 W 50 VA
Switching accuracy: ca. 2-5 % of final scale value
are equipped with non-contact NAMUR slotted proximity switches. They are particularly suitable for oil-filled measuring instruments and can be used in potentially explosive areas when using Ex-certified isolating amplifiers.
Nominal voltage: 8 V DC
Switching accuracy: approx. 0,5 % of final scale value
are equipped with non touching proximity switches. They should be preferable used with oil filled measuring instruments, for operating under low voltages and for small DC-loads, eg. for direct connection to a PLC.
Operating voltage: 10-30 V DC
Breaking capacity: below 100mA
Switching precision: approx. 0,5% of final scale value
are equipped with pneumatic proximity switches. They are used where air is already being used and/or no electric current is available.
Operating pressure: 1,4 bar
Admission pressure: approx. 0,1 bar
Outlet pressure: approx. 30 mbar Internal air consumption: approx. 30l/h
Standard with PG cable gland or oil-tight with plug and cable, completely mounted and wired.
Available in DN 100, DN 4 ½ “, DN 6”, DN 160